top of page
sizuphosloamadis

Descargar virtual sampler dk 2.7 full gratis: el programa que te ofrece miles de opciones y efectos



Two virtual vibraphones, V-M and V-B, reproduce faithfully the characteristic sound of two well-known vibraphone brands. The V-M is a virtual copy of a Musser vibraphone (USA) that belongs to the famous French vibraphonist Dany Doriz. The V-B is a virtual copy of a Bergerault vibraphone (France).




descargar virtual sampler dk 2.7 full gratis




YouTube Video Describing RevP2 to A1: 02/18/16 P2: Add: Auto Waterfall Transmit Low level adjustment. Key the radio and Click "Auto Wtr Level" to set Waterfall for transmit input level. Fix: Waterfall only, not displaying correctly due to addition of avgP, avgB previously. Auto Wtr Level turns off if you just in panadapter mode. 02/18/16 P1: Add: Auto Waterfall Low Level Adjustment. Just click the "Auto Wtr Level" button below the display area. 02/17/16 O9: Fix: Found mistake in Source code when compiled under VS2015 caused the check for atu.dll to fail, so Flex3000 units were using OLD ANT Tuning algorithm. Also Dttsp.dll now is updated to current 2015 v140 toolset, hopefully no issues. I embeded vc_redist_x86 into the DttSP.dll. 02/16/16: Figured out how to compile DttSP.dll under v140 platform toolset. Dumpbin showed v140 requires vc_redist.x86 since DttSP is a 32bit C application. Recompile DttSP.dll under C code generate runtime /MT (instead of /MD) will include all required DLL's 02/15/16 O8: Fix: Add toolTips to TXWaterID and Callsign box. Save the AvgP or AvgB settings in database. Right Click on Callsign Box to open up Folder where you put your own bitmap files to send to the waterfall. Right Click on the REC button to open up Folder where you will find SDRQuickAudio.wav files from your REC / PLAY use Right Click on the your current skin (Setup->Appearance->General->Skins->current skin) to open the Folder to the SKINS . 02/14/16 O7: Fix: Prevent (if you accidently hit the TX Waterfall ID with the Radio OFF) keying the Transmitter when the Radio is OFF (sitting idle) 02/13/16 O6: ADD: Flex3000 Now has 192k Sample Rate (you can view around 170khz on the screen at 1 time), in addition to the 10khz wide TX 02/13/16 O5: Fix: TX WaterID Now runs on its own background Thread (see video).Creates file when you change the Callsign text field. 02/12/16 O4: Fix: TX WaterID much faster to create image if running 96k or 192k Sample rates. Fix: Flex Audioplayer has a automatic resampler, but the code to make it work had some missing pieces, fixed the missing pieces, so now 48k waterfall resamples for 96k and 192k SR. 02/12/16 O3: Fix: TX WaterID labels: Creating->Transmit-Tx WaterID. Add Grayscale to database. Database name now: ke9ns1.dat 02/11/16 O2: ADD: Database to save mod settings: Callsign ID, Wide waterfall, etc. 02/11/16 O1: PowerSDR compiled under NET 4.5.2. PowerSDR.exe file slightly larger because Cdecl requires each function to have its own cleanup code. The Downside is that you must also copy over a "PowerSDR.exe.config" file becuase of the old FLEX1500USB.dll. NET 4.5 is supposed to be an improvment over the NET 3.5 PowerSDR was using. 02/11/16 Start learning DttSP: Update C++ code to VS2015 and recompile to SDK 8.1, which causes struct redef caused by time.h using timespec and pthread.h using the same timespec,but tv_sec is declared long instead of time_t, so I turned off the pthread.h version for now. also determined that not all of the DttSP is here. Completed full upgrade to NET 4.5 using CallingConvention = CallingConvetion.Cdecl in the DLLImport lines of win32.cs and dttsp.cs. Small change to app.config, set VS2015 to NET4.5 and recompile. (thanks to WA1GON for figuring it out) But also determined that you need to bring a config file along with the exe file due to an old DLL 02/11/16 N7: Fix KHZ freq entry. Turn off KHZ entry for VHF and above freq on both rx1 and rx2. 02/10/16 N6: Fix: Increase TX Bandwidth on Flex1500 and Flex3000 to 10khz wide. Fix: Improved Waterfall ID 24bit bitmap transmit. Automatically reduced the TX High filter down to 2.6khz during transmit, then back to its prior value. Still learning Bitmaps, and PCM and the conversion between them. 02/09/16 N5: Add: Waterfall ID will now load standard 24bit bitmap files as well as 8bpp 256 color bitmap files. 02/08/16 N4: Fix: VAC1 will automatically turn off when sending a TX waterfall ID, then back on when done. Add: Transmit 256 grayscale 8bpp bitmap images. Instructions: 1) Create a small 8bpp 256 color or grayscale bitmap image around 80w x 60h pixels and call it a short name, for example: test.bmp 2) Place that file in the folder %userprofile%\AppData\Roaming\FlexRadio Systems\PowerSDR v2.7.2\ (where the quickplay audio files go) 3) Change the "callsign" to the name of the file with a . at the end of the name (for example: test. ) and it will load test.bmp from the folder and send it. Warning: There is no file checking. If you do not follow these instructions, PowerSDR will crash. Your database should survive, as my database did. I provided a "test.bmp" file to place in the folder mentioned above.


How it works. 1) Type your Callsign into the box Callsign. 2) For TX on VFOA: VAC1 must of OFF, you can use VAC2. You cannot use VAC1 or 2 if you TX on VFOB 3) Click on the TX Water ID button to create and send the Waterfall ID4 4) The 1st time you click, there will be a noticable delay (very long delay at 192000) while the image is created before sending it, you MIC will be ON. 5) Subsequent Clicks on TX Water ID will start instantly (unless you change sample rate or callsign or mode). 6) The audio level can be controlled by going to the WAVE-> TX Gain adjustment. 7) Lower sample rates create the initial image faster, so less delay on the first click. 8) Bandpass is around 2.4khz wide starting at 150 hz 9) If your running 192000 samplerate, you will not see a very clear waterfall image. This is because there are only 4096 point to display around 170khz worth of information (40hz per pixel). It will still transmit clearly. You can only view waterfall images clearly at 96000 or 48000 sample rates 02/04/16 M10: Fix: I believe the studder in DJ console might be related to the PA temp/volts display which take .05 seconds to read and display. Made the Temp/volts display off by default, click on it to turn it on. It updates with the CPU, so whatever you set as the CPU Meter refresh rate is the refresh rate of the temp/volts when its ON. 02/03/16 M9: ADD: Check box in Setup->Display->Waterfall-> Enable Wider Waterfall. When checked this Increases waterfall bitmap size by factor of x2. By widening the waterfall left/right, you must go further up or down frequency to hit the edge of the bitmap. Hitting the edge causes a need to refresh the bitmap (which causes the deley ). The standard moving waterfall draw take .015 seconds, the wider waterfall takes .022 seconds. Older computers may by laggy with the wider waterfall area. Recompiled under VS2015 UPDATE 1. Font: Found somehow all console fonts got changed to MS SanSerif "Oblique". Trying to change back to "Regular". Swis721 is only for on the Meters. 02/02/16 M8: Feature ADD: On TX readjusts Panadapter Grid to span -90 to 0db, on RX Grid resets back to Low/High settings. 02/02/16 M7: Feature ADD: "Avg" button in Panafall affects Pan & Water. Now you can toggle have Avg Both, or Avg Pan fixed waterfall issue on resize of powerSDR window. 02/01/16 M6: Fix waterfall move on RX2. 01/31/16 M5: Fix clicking on meter now saves that meter for the next powerup. And learning some of the moving parts. 01/30/16 M4: Fix Flex mistake setting RX2 preamp offset to +14 (sometimes) when it should be -14 (just like RX1 on high mode). 01/30/16 M3: correct crashing issues caused by me going between VS2010 and VS2015. 01/29/16 M1: Fix blank space at bottom of screen caused by not copying the embedded font into the output directory 01/29/16 M: Feature ADD: DJ console 01/29/16 L8: Fixed Emedded Font compatibility issues with Win7 computers. (had to do with multiple fonts and not writing them properly into the privatefontcollection. 01/28/16:L : Feature Add: Freq Entry in KHZ or MHZ. (720 = .720 mhz) (7123 = 7.123 mhz) 01/28/16:K10: Fix: Digital display above meters, shift left 1 space for new font. Put Rev history in the About panel 01/27/16 K9: Fix: embedded the standard Windows Swis721 Font series into PowerSDR.exe. Enlarged the Edge type meter face. 01/27/16 K8: Feature Add: click on RX1 meter to change meter style. Fix edge meter size changing. 01/26/16 K7: Fix:RX2 low level band dBm following what you saved for the RX1 low level band dBm 01/26/16 K6: Fix:Edge meter red number too large. 01/26/16 K5: Fix:High level on TX Waterfall automatically sets to 0 db (you set the TX Low), since 0db is what your trying for anyway. 01/26/16 K4: Fix:Clean out areas of waterfall bitmap no or bad data. 01/26/16 K3: Fix:Turn off temp/volt on Flex 1500. Sometimes waterfall didnt move correctly due to timing issues between freq change and bitmap creation 01/25/16 K1: Added ATU.DLL to resources. This should fix Flex3000 ATU not showing up. 01/24/16 K: Now the entire Waterfall for both RX1 and RX2 moves with the spectrum of the panadapter. This leaves gaps on the left/right as you scroll since there is no data in those areas, but the waterfall will fill them in. This feature is not perfect, If you change ZOOM levels, it will not follow. 01/24/16 J: Add temp and volts to main screen, it updates along with the CPU% (hopefully calling FWC wont mess anything up?). Corrected the POWER on the TR7 meter by modifying the alg. Corrected the text and numbers on the Analog meter. Changed the FONT from the bla "Arial" and "MS Sans Serif" to the nicer "Swis721 BT" (italic). This I believe is the exact Font used by Icom on their displays. 01/23/1 I: Add Signal Peak hold meter for RX1 and RX2 meters (2nd red hold peak line) and db numbers hold peak with 2nd needle. Also corrected S9 readings for > 30 mhz to -93dbm 01/21/16 H: Add Menu item on the top line of PowerSDR for toggling Grayscale and Color for waterfall. Found Grayscale cuts the bandwidth down needed for remote operation. Also added toggle on/off fuction to Peak offset, Peak Power, Peak Freq values in lower right corner of display by mouse clicking any of those values. Also added hover tips to them. 01/18/16 G: Fix the RX1 or RX2 waterfall size messing up when you expand or shrink the PowerSDR console size. 01/17/16 G: Clean up and smooth the Analog meter lines (arcs). Now Analog meter movement(s) for everything except RX ADC(s). Renamed Waterfall "Mic Level" to "TX Level" since its not just for the mic input. 2ff7e9595c


0 views0 comments

Recent Posts

See All

Comentarios


bottom of page